The EUROLINE: A New Technique for Extensive Antibody Profiles

Principle of the Test

  • Membrane strips coated with thin parallel lines of several purified, biochemically characterized antigens are used as solid phase. The membranes are fixed as onto synthetic foil.
  • If the sample is positive, specific antibodies in the diluted serum sample attach to the antigens coupled to the solid phase.
  • In a second incubation step, the attached antibodies react with alkaline-phosphatase-labelled anti-human antibodies.
  • In a third step, the bound antibodies are stained with a chromogen/substrate solution which is capable of promoting a color reaction. An intense dark band at the line of the corresponding antigen appears if the serum sample contains specific antibodies.
  • Depending on the spectrum of antigens used, it is possible to analyze several antibodies next to each other and simultaneously under identical conditions.

Easy Handling, Reliable and Simple Evaluation

Incubated EUROLINE ANA-Profile 3 test strips
  • A separate membrane strip is incubated for each serum sample.
  • Total time for performing the analysis is about 105 minutes.
  • The incubation can be automated using the EUROBlotMaster.
  • All incubation steps proceed at room temperature.
  • The antigen bands are located at exactly defined positions, which means that the evaluation of the test is much simpler than for Westernblots. 
  • Correct completion of the individual incubation steps is indicated by staining of the control band on each EUROLINE test strip. 
  • Positive and negative results can be easily and reliable differentiated from each other. The intensity of the antigen bands correlates with the antibody titer. 
  • The antigens used are highly pure, mostly isolated by affinity chomatography. The membrane strips do not contain any superfluous proteins which might cause unspecific positive results.  
  • The incubated EUROLINE test strips can be stored for long periods. Results can be easily documented. 
  • The program EUROLineScan from EUROIMMUN has been developed to enable quantitative evaluation of EUROLINE test strips, to facilitate management of data, and to provide detailed documentation of results. First, the incubated EUROLINE test strips are scanned using a flatbed scanner. EUROLineScan recognizes the position of the strips, even if they have been placed inexactly, identifies the bands, and measures their intensity. The results are then saved together with the image data. A separate results sheet can be produced for each patient.

To top

Automatic evaluation of results using EUROLineScan

EUROBlotCamera (left); EUROBlotScanner (right)
  • For all EUROIMMUN blot systems: EUROLINE, EUROLINE-WB, Westernblot.
  • For all areas: autoimmune diagnostics, infectious serology and allergy.
  • EUROBlotCamera: digitalisation of strips while in the incubation tray.
  • EUROBlotScanner: digitalisation of strips using flatbed scanner.
  • Fully automated identification, quantitation and assignment of bands.
  • Option to modify results (changes are automatically documented).
  • Complete results obtained just a few minutes after finishing the incubation.
  • Fully automated administration and documentation of extensive individual data.
  • Electronic archiving of all images and data (avoids the need to store potentially infectious blot strips).

EUROIMMUN US • 429 Rockaway Valley Road, Unit 1200 • Boonton Twp. NJ 07005
Phone 973-402-6101 & 800-913-2022 • FAX 973-402-2551 • Email info@euroimmun.us
ImmunofluorescenceMicroplate-ELISA

EUROLINE

  • Principle
  • Incubation
  • Automation
Westernblots/EUROLINE-WBDevices/Software

FDA cleared : For In vitro Diagnostic use :

Autoimmune serology

Infectious serology

Headlines / NEWS:

ANCA diagnostics at a glance

New Standard in the Diagnosis of Wegener’s Granulomatosis: The EUROIMMUN Anti-PR3-hn-hr ELISA

SLE Diagnostics Using the Anti-dsDNA-NcX ELISA: The Highest Specificity, more Sensitive than the Farr Assay

Myositis Blot (Mi-2,Ku,PM-Scl, Jo-1, PL-7, PL-12, R0-52)

Evaluated by international experts: EUROIMMUN test systems for the serological diagnosis of rheumatic diseases

EUROStar II: The new microscope for immunofluorescence

EUROLineScan for automated evaluation of blot-based assays

EUROBlotMaster for automated incubation

EUROIMMUN Analyzer I - The new automated ELISA system for microtiter plates

For Research Use Only:

Diagnosis of autoimmune hepatitis using cell line VSM47: A new way to reliably determine anti-F-actin antibodies

Anti-Borrelia EUROLINE-RN-AT: A line blot using recombinant and native authentic Borrelia antigens. Broad antigen spectrum. A new alternative!

Borrelia (VlsE) Blot

M2-3E: A Highly Suited Designer Antigen for the Determination of Antibodies against M2 in the Diagnosis of PBC

Anti-Gliadin(GAF-3X) ELISA: A New Milestone in the Serological Diagnosis of Coeliac Disease

BIOCHIP Mosaics™ for Serological Diagnostics of Tropical Diseases and Special Infections

ADMA (asymmetric dimethylarginine) for the quantitative determination of Cardiovascular Disease

Calendar:

July 25-29 2010 AACC

August 7-10, 2010 AMLI

Nov 8-10 2010 ACR

Nov. 14 - 17 - Society for Neuroscience

HomeAbout usJobs and Careers
EUROIMMUN Medizinische Labordiagnostika AGEUROIMMUN Medizinische Labordiagnostika AG
  • Techniques
    • Immunofluorescence
      • Description
      • Incubation
      • Automation
    • Microplate-ELISA
      • Description
      • Incubation
      • Automation
    • EUROLINE
      • Principle
      • Incubation
      • Automation
    • Westernblots/EUROLINE-WB
      • Principle
      • Incubation
      • Automation
    • Devices/Software
  • Applications
    • Determination of Autoantibodies
      • AAb against Cell Nuclei (ANA)
      • AAb against dsDNA
      • AAb against CCP
      • AAb against Liver Antigens
      • AAb against Neuronal Antigens
      • AAb in Diabetes mellitus
      • AAb against Granulocytes (ANCA)
      • Ab against Endomysium and Gliadin
    • Infectious Serology
      • Ab against Borrelia/TBE Virus
      • Ab against Epstein-Barr Virus (EBV)
      • Ab against Helicobacter pylori
      • Antibodies against Chlamydia
      • Ab against Herpes-simplex Virus (HSV)
      • Antibodies against Emerging Viruses
      • BIOCHIP Mosaics™ for Infectious Serology
      • Additional Reagents for the Determination of Acute Infections
    • Allergology
  • Products
    • Indirect Immunofluorescence
    • Microplate ELISA
    • Blot Techniques
    • Devices/Software
  • Downloads
    • Product catalogue
    • Flyer
  • Support
    • Technical support
    • IFA Image support
  • Contact
    • EUROIMMUN US
    • EUROIMMUN Corporation Deutschland
    • EUROIMMUN Subsidiaries
    • Institute for Quality Assurance
    • Institute for experimental Immunology